Explicit model rules
Capacity
Stored energy may never exceed 100 Wh.
Charge
Accepted input × 0.90 is stored; the other 10% is lost.
Discharge
Energy removed × 0.92 becomes output; the other 8% is lost.
Round trip
0.90 × 0.92 = 82.8% ideal stored-to-useful efficiency.
Requests
Charge in 25 Wh requests; discharge in 30 Wh requests, limited by available storage.
Overcharge
A charge is clamped before acceptance. Rejected energy never enters the balance.
Max accepted charge input = (Capacity − Stored) ÷ 0.90
Conservation: Input = Stored + Output + Lost