Windmill orientation lab
Align for power,
not by instinct.
The rotor works best when its plane faces the wind. Rotate the cap and watch the indicative power change while the grain-processing demand stays fixed.
Grain-processing load is fixed at 4.0 kW in every orientation.
Current cap bearing
090° / 360°
Available power
Indicative model
Wind power reaching the rotor
10.0kW
0 kW10.0 kW maximum
To grain4.0 kW
Alignment0°
Load met100%
Load met · 6.0 kW available surplus
Available power is shown independently of the load. Grain power is capped at the unchanged 4.0 kW processing demand.
Compare orientations
Both snapshots use the same 8.0 m/s wind and the same 4.0 kW grain load.
Simplified model & assumptions
Pavailable = ½ρAv³ · max(0, cos Δ)³
Pgrain = min(Pavailable, 4.0 kW)
- Air density ρ = 1.225 kg/m³.
- Effective rotor area A = 24 m².
- Wind speed v = 8.0 m/s, held constant.
- Δ is the shortest signed angle between cap and wind bearings.
- The cosine-cubed factor represents projected area plus a simplified loss with misalignment.
- No turbulence, wind-speed variation, drivetrain efficiency, startup behavior, or detailed aerodynamics are modeled.
- The 4.0 kW grain-processing requirement never changes. Any surplus is not assigned to the grain process.