Ideal Transformer Bench

Same input.
Different turns.

Two lossless transformers share one alternating source. Each load receives the same real power, so a higher output voltage produces a lower output current.

Shared input 120 V RMS
Load power 120 W
Input current 1.00 A RMS
Experiment controls Live model
Primary Secondary Current

Transformer T1

1 : 1
V₂ = 1 × V₁
I₂ = 1 × I₁
Output V 120.0 V
Output I 1.00 A
Load R 12.0 Ω

Transformer T2

1 : 2
V₂ = 2 × V₁
I₂ = ½ × I₁
Output V 240.0 V
Output I 0.50 A
Load R 48.0 Ω

Equal-power relationship

IDEAL
Voltage ratio V₂/V₁ = N₂/N₁
Current ratio I₂/I₁ = N₁/N₂
Power P₁ = P₂

At fixed power, I₂ = P / V₂. Therefore doubling the secondary voltage halves the secondary current. The resistive load values also change so both models still consume equal power.