Low-poly electromagnetic model
Ideal Two-Coil Transformer
A closed magnetic core carries one shared alternating flux. The primary and secondary windings occupy opposite limbs of the same magnetic circuit.
Ideal linked-flux approximation
Φ
p
(t) ≈ Φ
s
(t) = Φ(t)
Φ(t) = Φ
max
sin(ωt)
λ
p
= N
p
Φ, λ
s
= N
s
Φ
V
p
/ V
s
= N
p
/ N
s
=
32 / 16 = 2
Ideal approximation: leakage flux, fringing, winding resistance, magnetizing current, and core loss are neglected.
Drag to orbit
Scroll to zoom
Reset view